Government mail service may be affected by the Canada Post labour disruption. See how to send and receive government mail during this time.
Short form minor works contract
Section number | Section name | Revision date |
---|---|---|
00 40 10 SFMWC | Specifier's Guide | 2022-10-31 |
00 41 00 SFMWC | Bid and Contract Form | 2022-10-31 |
00 70 00 SFMWC | Instructions to Bidders and Conditions of Contract | 2024-05-02 |
Small projects master specification
Section number | Section name | Revision date |
---|---|---|
00 00 00SP | Specifier's Guide | 2022-10-31 |
00 00 10SP | Introductory Information | 2023-09-07 |
00 01 16SP | List of Drawing Sheets | 2015-03-12 |
00 11 17SP | Letter of Invitation to Bid | 2015-03-12 |
00 21 14SP | Instructions to Bidders | 2024-05-02 |
00 41 14SP | Stipulated Price Bid and Contract Form | 2022-10-31 |
00 41 49SP | Unit Price Bid and Contract Form | 2023-07-20 |
00 43 13SP | Bid Security | 2022-10-31 |
00 61 13SP | Contract Security | 2023-09-07 |
00 72 14SP | General Conditions of Contract – includes link to 00 73 80B-A eForm – Statutory Declaration of Payment Distribution | 2023-09-07 |
01 00 15SP | General Requirements | 2022-10-31 |
01 19 80SP | Schedule of Work | 2015-03-12 |
01 26 63SP | Change Order Procedures | 2023-09-07 |
Seniors lodge master specification
Division 07 – Thermal and moisture protection
Section number | Section name | Revision date |
---|---|---|
07 46 33SL | Vinyl Siding and Metal Soffits and Fascia | 2008-05-01 |
Division 08 – Doors and windows
Section number | Section name | Revision date |
---|---|---|
08 11 69SL | Aluminum Storm Doors | 2008-05-01 |
Division 10 – Specialities
Section number | Section name | Revision date |
---|---|---|
10 44 16SL | Hand Held Fire Extinguishers | 2008-05-01 |
Division 20 – Common mechanical requirements
Section number | Section name | Revision date |
---|---|---|
20 00 13SL | General Mechanical Requirements | 2008-05-01 |
20 05 23SL | Valves | 2008-05-01 |
20 05 25SL | Meters, Pressure Gauges and Thermometers | 2008-05-01 |
20 05 29SL | Hangers and Supports | 2008-05-01 |
20 05 43SL | Mechanical Identification | 2008-05-01 |
20 15 00SL | Tanks | 2008-05-01 |
20 15 00 01SL | Detail – Expansion Tank – Pneumatic Vessels | 2008-05-01 |
20 15 00 03SL | Detail – Domestic Hot Water Storage Tank Detail | 2008-05-01 |
20 20 10SL | Pipe and Pipe Fittings | 2008-05-01 |
20 20 30SL | Piping and Equipment Insulation | 2008-05-01 |
20 20 60SL | Pumps | 2008-05-01 |
20 40 35SL | Hot Water Specialties | 2008-05-01 |
20 40 40SL | Refrigeration Specialties | 2008-05-01 |
Division 21 – Fire suppression
Section number | Section name | Revision date |
---|---|---|
21 13 10SL | Sprinkler Equipment | 2008-05-01 |
Division 22 – Plumbing
Section number | Section name | Revision date |
---|---|---|
22 05 90SL | Plumbing Specialties | 2008-05-01 |
22 42 00SL | Plumbing Fixtures and Trim | 2008-05-01 |
Division 23 – Heating, ventilating and air conditioning
Section number | Section name | Revision date |
---|---|---|
23 07 00SL | Ductwork and Breeching Insulation | 2008-05-01 |
23 08 94SL | Mechanical Systems Starting, Testing, Balancing and Demonstration | 2008-05-01 |
23 09 11SL | Mechanical Equipment Controls | 2008-05-01 |
23 25 00SL | Cleaning and Chemical Treatment of Piped Systems | 2008-05-01 |
23 25 01.01SL | Detail – Chemical Pot Feeder (Replaces 23 25 00.01) | 2008-05-01 |
23 25 01.02SL | Detail – Installation of Chemical Pot Feeder, By-pass Filter (Replaces 23 25 00.02) | 2008-05-01 |
23 31 13SL | Ductwork | 2008-05-01 |
23 31 31SL | Ductwork Accessories and Air Outlets | 2008-05-01 |
23 34 00SL | Fans | 2008-05-01 |
23 51 00SL | Breeching and Chimneys | 2008-05-01 |
23 52 00SL | Heating Boilers | 2008-05-01 |
23 54 16SL | Forced Air Furnaces | 2008-05-01 |
23 55 01SL | Direct Fired Make-up Air Units | 2008-05-01 |
23 63 13SL | Air Cooled Condensing Units | 2008-05-01 |
23 73 10SL | Air Handling Units | 2008-05-01 |
23 81 19SL | Packaged Roof Top Heating / Cooling Units | 2008-05-01 |
23 82 05SL | Terminal Heat Transfer Units | 2008-05-01 |
Division 26 – Electrical
Section number | Section name | Revision date |
---|---|---|
26 00 05SL | Basic Electrical Requirements | 2008-05-01 |
26 05 01SL | Basic Electrical Materials and Methods | 2008-05-01 |
26 08 11SL | Electrical Starting and Testing | 2008-05-01 |
26 09 15SL | Parking Plug-in Control | 2008-05-01 |
26 24 05SL | Service and Distribution | 2008-05-01 |
26 50 20SL | Lighting | 2008-05-01 |
Division 27 – Communications
Section number | Section name | Revision date |
---|---|---|
27 10 20SL | Telephone | 2008-05-01 |
27 41 00SL | TV System | 2008-05-01 |
27 51 14SL | Emergency Call, Paging and Door Monitoring Systems | 2008-05-01 |
27 51 16SL | Public Address System | 2008-05-01 |
Division 28 – Electronic safety and security
Section number | Section name | Revision date |
---|---|---|
28 31 01SL | Hard Wired Fire Alarm System | 2008-05-01 |
Publication
Contact
Connect with Technical Services and Procurement Branch:
Phone: 780-422-7456
Fax: 780-422-7479
Email: [email protected]
Email: [email protected]
Previous
Contractor forms